Austin mixed-use HVAC scope, split by occupancy

Austin requests often stack apartments over retail or convert an office floor to labs. Each occupancy gets its own equipment and duct subtotal, and shared outdoor air is counted once.

Remote service coverage. This page represents no local branch office.

Which Austin occupancies must not share a subtotal?

Mixed-use drawings in Austin reuse the same floor plate for different mechanical systems. A residential level may be a horizontal fan-coil or a split heat pump per apartment. The retail shell under it may be an empty curb and a capped outside-air duct. The amenity deck may have a dedicated outdoor-air unit. Putting those into one “HVAC” lump hides the buyout.

Shared ventilation is the piece that gets double counted. If a rooftop energy-recovery unit feeds several floors, count the unit once and reference the riser. Do not also count it inside each tenant. Corridor makeup air follows the same rule.

Sample rows for an Austin podium building

RowUnitOccupancy
Apartment heat pump, scheduled nominal tonsEAResidential. Include the line-set length only if the drawings or a typical detail dimension it.
Retail shell curb and capped supply mainEA / LFShell. Tenant distribution is an alternate until a tenant plan exists.
Dedicated outdoor-air unit on the amenity roofEAShared. One count, with the floors noted.
Dryer or bath exhaust riser, residential stackLFKeep exhaust metal and roof cap separate from supply duct.
Lab exhaust fan, if a lab floor is in the setEASpecialist. Do not price it as a toilet fan because both are exhaust.

Energy code is a responsibility question, not a quantity

Austin projects often ask who completes energy-code documentation and duct-leakage tests. Those are not produced by measuring duct. The takeoff can list the equipment efficiency exactly as scheduled, which a code form might need, but filling the form, sealing the calculation, or certifying leakage is outside a standard estimating assignment. Say so in the proposal if the invitation to bid is vague.

Documents that change the Austin fee

Send architectural floor plans for every occupancy, the mechanical schedules, roof plan, and any tenant criteria manual. If the lab or kitchen is performance-specified rather than drawn, the quote should say the quantities stop where the drawings stop. A priced estimate still needs your equipment quotes. The estimating fee is for the desk work, not the installed cost of the building.

Common questions

Questions about HVAC estimating in Austin

How are Austin apartments over retail measured?

Give the residential fan-coils or split systems their own schedule. Give the retail rooftop or split system another. Shafts and corridors that serve both are a shared group, listed once, with the floors they feed.

Does an Austin takeoff include energy-code forms?

No. A quantity takeoff records the equipment the drawings show. Energy-code compliance forms, duct-leakage testing and commissioning are included only when the quote says so.

What if one floor is a lab?

Pull that floor out before measuring. Fume exhaust, specialty filtration and once-through air are not office VAV quantities. Confirm who owns the lab design.

Where should the Austin job address go?

On the quote request, in full. Downtown, a campus, and a suburban municipal utility district do not share a review office just because the mailing city is Austin.

Project address, not a Austin office

Send the street address with the drawings. Labor rates, freight, access and the reviewing authority come from that job, not from the city name on this page.