Remote estimating · Houston, TX

Houston central-plant and medical HVAC takeoffs

Houston bids often split a central plant from the air distribution, then split comfort cooling from medical or laboratory exhaust. Send the plant schedules and the floor plans together so those scopes are not priced as one lump.

Remote service coverage. This page represents no local branch office.

What belongs in a Houston central-plant takeoff?

A Houston mechanical bid often has two different jobs on one set of drawings: the plant that makes chilled water, and the distribution that delivers air and water to the floors. Price them as separate assemblies. The chiller, cooling tower, pumps and chemical treatment sit on an equipment schedule. The chilled-water and condenser-water mains, valves, specialties and insulation sit on the riser and plan drawings. Neither total replaces the other.

Occupied healthcare work needs a third split. Comfort air for offices and lobbies is not the same system as isolation exhaust, operating-room air changes, or a laboratory hood. If the sheets do not name the service on the duct, stop and list the run as unresolved instead of calling it supply air.

Sample line items for a Houston plant and distribution bid

These rows show how a schedule should read. They are a format example, not a Houston price and not a completed project.

ItemUnitWhy it is its own row
Water-cooled chiller, tag CH-2EAMatch the schedule tonnage, voltage and starter. Do not infer capacity from a floor-area rule.
Cooling tower, tag CT-1, with basin heaters if specifiedEABasin heat, vibration isolation and access ladders are accessories, not part of the tower count.
Condenser-water pipe, 8 inchLFKeep pipe length separate from grooved couplings, valves and hangers.
Isolation exhaust duct, welded stainless if specifiedLFA process or medical material spec cannot be measured as galvanized comfort duct.
Outdoor-air handler with reheat coilEAHumidity control is an equipment row plus the coil connection, not a percentage of cooling tons.

How Houston drawings usually fail a bid review

Plant rooms are revised by addendum while the floor plans stay on an older issue. Record both issue dates. A new chiller selection can change nozzle sizes, primary pipe, electrical connection and concrete housekeeping pads. Those changes belong in a revision column, not folded into the original quantities.

Roof equipment also needs a responsibility check. Screen walls, structural curbs, lightning protection and roofing patches are often outside the mechanical contract even when the unit is shown on the mechanical roof plan. List them as exclusions unless the specifications assign them to Division 23.

What to send for a Houston quote

Send the equipment schedules, riser diagrams, enlarged plant plans, air-balance diagrams if you have them, and the specification sections for chillers, towers, duct and insulation. Name the job address and whether the building will stay occupied. Say if you want quantities only or a priced estimate that uses your supplier quotes and labor rates. Freight to a Houston dock, crane time and temporary cooling are allowances until those quotes exist.

Common questions

Questions about HVAC estimating in Houston

What should a Houston central-plant takeoff keep separate?

Count chillers, towers, pumps and air handlers from the equipment schedule, then measure the chilled-water, condenser-water and air-distribution systems on their own sheets. A plant-room total does not include risers, valves, insulation or reconnection at existing headers.

How should occupied medical work in Houston be flagged?

Mark operating rooms, isolation exhaust, and after-hours phasing as their own line groups. Shutdown windows and temporary cooling are cost items only when the documents or your instructions include them.

Does Gulf Coast humidity change the quantities?

Only when the drawings show outdoor-air, reheat or dehumidification equipment. Count that equipment and its duct or pipe from the schedules. Do not add a humidity factor that the design did not draw.

Is there a Houston office that visits the site?

No. Coverage is remote. The job address is used for delivery, access and the authority named on the drawings. A site survey is a separate agreement.

Project address, not a Houston office

Send the street address with the drawings. Labor rates, freight, access and the reviewing authority come from that job, not from the city name on this page.

Other names in Greater Houston

Browse service coverage →

Open a map of Houston, TX

The map shows the city. It is not an office location, and it does not load inside this page.