Remote estimating · Denver, CO

Denver heating-plant and altitude-aware equipment counts

Denver schedules may already show altitude-adjusted equipment. The takeoff counts that scheduled unit. It does not re-rate capacity, and it treats snow and roof access as labor questions.

Remote service coverage. This page represents no local branch office.

What does altitude change in a Denver takeoff?

It changes the note you write beside the equipment, not the arithmetic of the count. Manufacturers derate cooling equipment at elevation. If the schedule lists a model and a capacity, that is the row. If a contractor asks to “add tons for Denver,” the correct response is to request a revised schedule or a separate load calculation. Inventing capacity is design.

Heating is easy to undercount because the cooling conversation is louder. Look for boilers, pumps, hot-water coils, electric duct heaters, or gas heat in packaged units. A building can have all of those in different zones. Each gets a row.

Sample Denver rows

ItemUnitAltitude or winter note
Air handler, scheduled CFM and modelEADo not substitute a sea-level equivalent model.
Condensing boiler, tag B-1EAInclude the scheduled vent material as its own row if specified.
Heating-water pipe, by sizeLFSeparate from chilled water.
Roof duct with specified insulationLFSnow guards or equipment screens only if detailed.
Heat trace, exposed piping, if specifiedLFExcluded when the spec does not call for it.

Roof access is a labor assumption

Setting units on a Denver roof in winter can limit crane days and add protection of the membrane. That belongs in the labor narrative and the exclusions. The number of curbs is still the number of curbs drawn. If the structural plans show a different curb opening than the mechanical plans, log the conflict before anyone buys a curb.

Hydronic specialties matter in this climate: air separators, expansion tanks, and glycol fill if specified. Count them from the diagram. Glycol is a material allowance with a concentration only when the spec states one.

Send

Schedules, boiler or pump diagrams, roof plans, insulation specs, and architectural roof height if crane access is in your question list. Provide labor rates for a priced estimate. State whether glycol and heat trace are in your trade’s scope.

Common questions

Questions about HVAC estimating in Denver

Should the estimator re-rate equipment for Denver altitude?

No. Use the model and capacity printed on the schedule. Re-rating is an engineering task. If the schedule is silent, list the unit as an open item.

How are heating and cooling both covered?

Heating water or gas heat is one subtotal. Chilled water or DX cooling is another. Many Denver buildings have a real heating plant plus a smaller cooling plant. Do not drop the boilers.

What does snow change?

Labor and equipment setting: crane windows, roof protection, heat trace if specified. It does not change measured duct length.

Is a mountain site the same as a Denver city site?

Send the job address. Design temperatures and access follow the site, and the drawings already reflect the designer's choices.

Project address, not a Denver office

Send the street address with the drawings. Labor rates, freight, access and the reviewing authority come from that job, not from the city name on this page.

Browse service coverage →

Open a map of Denver, CO

The map shows the city. It is not an office location, and it does not load inside this page.